Motors with more than four poles are a lot less common and just employed for special applications. In this instance, the motor may not have the ability to operate the automated equipment as expected. In america, although IEC motors are from time to time used, NEMA motors are somewhat more common. One of the most frequently used electrical motors is induction motor. A more efficient electric motor means you may use a more compact battery to accomplish a given range, which not just lowers the price tag, but in addition lowers the battery's weight and footprint. Some single-phase split-phase motors that are created for specific applications could have the connection between the primary winding and the start circuit connected internally so the rotation cannot be changed.

Send Inquiry Now

Our Product Detail

This is the description of Why Everyone Is Talking About Ac Induction Motor

Standard Features

  • Sinusoidal power supply of 3000v to 11,000 V
  • Motors manufactured in 2 to 16 poles
  • welded steel plates for frame 355 to 1000
  • Cooling methods used:
    - Open self-ventilated;
    - Self-ventilated by ducts, air inlet and outlet;
    - Forced ventilated, air inlet and outlet by ducts;
    - Forced ventilation, cooling on top of motor;
    - air-to-air Cooler ;

- Air-to-water Cooler ;

other cooling methods can be design

  • Mounting: B3
  • Degree of Protection: IP23 to IP55
  • Service duty: (S1)
  • Class of insulation: F
  • Service Factor: 1.0
  • Ambient temperature: 40 °C
  • Altitude: 1000 m
  • Temperature detector: Pt100
  • Single phase space heater
  • Bearings: Rolling bearing or Sleeve bearings
  • Electrically insulated non-drive end bearing for frames 450 and above, when connected directly to the power supply
  • Stainless steel nameplate
  • Grounding lug on the frame and terminal box
  • Grounding brush on drive end shaft for frame size 450 and above
  • Stainless steel slip rings

 

Optional Features

  • VFD application
  • Service Factor: 1.15
  • Class of insulation: H
  • Temperature rise: 105°K for class F
  • Temperature rise: 125°K for class H
  • Ambient temperature above 40 °C (on request)
  • Altitude above 1000 m (on request)
  • Mountings: B5, B35, V1, V3, V5, V6, V18, V19, V36
  • Degree of Protection IPW55 and above
  • Classified area application: Ex-n, Ex-e, Ex-p
  • Special balance
  • Base: rail, sliding base, extended feet, rebuilt feet, anchorage plate
  • Steel welded terminal box in different sizes, based on internal available space
  • Power factor correction capacitors
  • Non-reversion ratchet
  • Centrifugal switch
  • Temperature detector: Thermistor (PTC or NTC)
  • Temperature detector: Thermostat (Bimetallic)
  • Two energized power terminal boxes
  • One or more accessory terminal boxes
  • Shaft: Special dimensions, double shaft end, tapered, hollow, special steel
  • Sleeve bearing
  • Oil lubricated bearing
  • Special bearing (overdesigned) for axial or radial thrust
  • Special painting
  • Terminal block for low voltage
  • Cable gland in the terminal box entrance
  • Protection against voltage surge: Lighting arrestors and Capacitors
  • Aluminum, copper or brass rotor
  • Vibration detector
  • Noise suppressor in the air inlet and outlet
  • Encoder
  • Tachogenerator
  • CT for differential and integral protection
  • Bearing thermometer with gauge with/without contacts
  • Signal transducer
  • Independent hydraulic oil circulation system for sleeve bearing
  • Electrically insulated non-drive end bearing for all frame sizes with driven by frequency drive
  • Both bearings are electrically insulated
  • Grounding brush on drive end bearing for all frames when driven by frequency converter (except for classified area)

YR

These motors can be designed with configuration to meet cooling method and degree of protection requirements of different kinds of applications.

 

 

Motors with more than four poles are a lot less common and just employed for special applications. In this instance, the motor may not have the ability to operate the automated equipment as expected. In america, although IEC motors are from time to time used, NEMA motors are somewhat more common. One of the most frequently used electrical motors is induction motor. A more efficient electric motor means you may use a more compact battery to accomplish a given range, which not just lowers the price tag, but in addition lowers the battery's weight and footprint. Some single-phase split-phase motors that are created for specific applications could have the connection between the primary winding and the start circuit connected internally so the rotation cannot be changed.

 

A linear motor is similar to an ac motor, but it's unwrapped and out flat. On the flip side, in the event the motor is given without a fan, then it has to be significantly oversized to permit for the heating when it isn't being cooled by water. This motor requires no modification. These motors are designed to meet specific application requirements and are generally known as above NEMA motors. They may be called'universal' motors because they can operate on DC. Permanent magnet motors have zero demand for this since they are made using, since the name hints at, permanently magnetic materials. Permanent Magnet Motors Permanent magnet motors are somewhat more costly than induction motors, but they're also a whole lot more compact and energy efficient, resulting in low operating expenses.

 

 

 

Since spinning induction machines produce little if any voltage when de-excited, they're simpler to protect. Expert tools and support will make it possible for you to fine tune and receive the the majority of your motor. The absolute most difficult application is as soon as the motor will normally be utilized in air, but occasionally will be submerged.

 

Hopefully, down the street, you will be able to bring the dual-motor option to other variants. More than 1 motor option may be appropriate for any given project. This feature is quite tricky to attain with different motors esp.

 

 

Vibration is NOT the best method to monitor most electrical troubles and that fact has to be recognized. The rotor is likewise not a magnet, though it's attracted by a magnet. It will become passively magnetized by this field. The rotor of a single motor is linked to the stator of the other. It featured an extremely unusual and hard to address shaft and the front bearing was actually open to permit lubrication directly from the Ford differential it was created to mate with.

 

There are essentially two kinds of induction motors. They are more difficult to understand. Thus, with regard to all features, it's better to go with AC induction motor rather than every other motor. The first action to do in an AC motor is to make a rotating field. There are many kinds of AC motors, yet this course focuses on three-phase AC induction motors, the most frequently encountered kind of motor employed in industrial applications. There are a few sorts of basic AC motors you're able to build.

 

Description

M Line motors are manufactured in different configurations in reference to cooling methods and degree of protection, allowing the machine to be designed as suitable as possible to meet operation and environment requirements.

Motors in frame sizes IEC 280 to 560 are manufactured in cast iron, while frame sizes IEC 630 and above are fabricated in welded steel plates.

Standard Features

  • Sinusoidal power supply of 220 to 13,800 V
  • Motors manufactured in 4 to 12 poles
  • Cast iron frames 280 to 560 and welded steel plates for frame 630 to 1800
  • Cooling methods used:
    - Open self-ventilated;
    - Self-ventilated by ducts, air inlet and outlet;
    - Forced ventilated, air inlet and outlet by ducts;
    - Forced ventilation, cooling on top of motor;
    - Self-ventilated with air-to-air heat exchanger, heat exchanger on top of motor;
    - Self-ventilated with air-to-air heat exchanger, heat exchanger around the stator;
    - Forced ventilation in the air internal and external circuit, air-to-air heat exchanger;
    - Air-to-water heat exchanger;
    - Air-to-water heat exchanger, forced ventilation in the air internal circuit
  • Mounting: B3
  • Degree of Protection: IP23 to IP55
  • Service duty: (S1)
  • Class of insulation: F
  • Service Factor: 1.0
  • Temperature rise: 80 °C
  • Ambient temperature: 40 °C
  • Altitude: 1000 m
  • Temperature detector: Pt100, 1 per bearing with 3 wires
  • Temperature detector: Pt100, 2 per phase with 3 wires
  • Two accessory terminal boxes, one for signal accessories and the other for those accessories requiring power supply (space heaters)
  • Single phase space heater
  • Labyrinth tachonite in grease lubricated bearings
  • Grease lubricated bearings:
    - For 4 pole motors in the following frame sizes:
    - Up to frame 560 (inclusive) for 60 and 50 Hz;
    - Grease lubricated bearings for 6 pole motors and above
  • Sleeve bearings:
    - For 4 pole motors in frame 630
  • Electrically insulated non-drive end bearing for frames 450 and above, when connected directly to the power supply
  • Painting: Acrylic polyurethane Polyamide epoxy (Final coat: Blue RAL 5007)
  • Stainless steel nameplate
  • Grounding lug on the frame and terminal box
  • Stainless steel slip rings
  • Rotor terminal box separated from stator terminal box
  • Compartment of slip rings and brushes separated from stator and rotor, behind the non-drive end bearing
  • Grounding brush on the drive end shaft for frames 450 and up
  • Automatic / manual brush lifting system
  • 03 connection terminals in the power terminal box for high voltage (with terminal block)
  • 06 loose power connection leads for low voltage (without terminal block)

 